Pay attention to supplementary information for the following components:
The compressor in a S2125/F2120/F2040 is inverter-controlled. The compressor’s power is adjusted based on the demand and routed to heating, hot water or cooling.
SMO 20 is supplied with a heating control system, which means that the heating supply to the house takes place according to selected settings. When connecting to a system with thermostats on all radiators (or underfloor heating coils), either a bypass valve must be fitted or some of the thermostats must be removed to ensure there is sufficient flow. For more information about heat production, see the Installer Manual.
If hot water heating is required, an external water heater/accumulator tank is docked.
When there is demand for hot water, SMO 20 prioritises this and switches to hot water mode. There is no heat production in this mode.
If the hot water temperature exceeds 60 °C, the installation must be supplemented with a mixing valve.
For more information about hot water production, see the manual for SMO 20 and/or the water heater’s/accumulator tank’s manual.
An external heating medium pump can be connected to SMO 20 via the AUX output.
If there is a large pressure drop over the brine side, an external brine pump may be required.
The system should be supplemented with an extra water heater, if a large bath tub or other significant consumer of hot water is installed.
Cooling and heating are distributed via the same climate system.
When there is a risk of condensation, components and climate systems must be insulated against condensation in accordance with current standards and provisions.
Via AUX, separate cooling and heating systems can be connected via a reversing valve. The cooling system is connected after the heat pump. When cooling is required (activated from the outdoor temperature sensor AA35-BT1 and room sensor AA35-BT50, where applicable), the shunt valve EQ1-QN12 and the circulation pump AA35-GP12 are activated.
When there is a risk of condensation, components and climate systems must be insulated against condensation in accordance with current standards and provisions.
See the valve’s manual for a port description.
Cooling in a 4-pipe system cannot be combined with hot water circulation as SMO 20 only has one AUX output.
Additional heat that is connected directly to SMO 20. The additional heat is used for heat production.
For more information about step-controlled additional heat, see the Installer Manual.
This function enables step-controlled additional heat to help with heating/hot water production.
With SMO 20, three relays can be used for additional heat control, which then gives max. 3 linear or 7 binary steps.
The flow through the additional heat is ensured by the charge pump (GP12).
For more information about step-controlled additional heat, see the Installer Manual.
Used to produce hot water at the same time as the heat pump prioritises other demands.
An immersion heater in a tank can also be used if a higher hot water temperature is required than can be produced by the heat pump.
This function enables district heating additional heat to assist with heating.
A 3-pipe-connected buffer vessel is used when the system volume in the climate system is below the minimum recommended volume for the heat pump and/or the flow in the heating system is restricted without control.
For further information, see the Installer Manual for the accessory.
A circulation pump can be controlled by SMO 20 via the AUX output, to circulate the hot water. The circulating water must have a temperature that prevents bacterial growth and scalding, and national standards must be met. See the appropriate Installer Manual for more information. Hot water circulation cannot be combined with cooling in a 4-pipe system because SMO 20 only has one AUX output.
Designation |
Name |
Specification |
Part No. |
Comments |
---|---|---|---|---|
-AA35 |
Control module |
SMO 20 |
067 224 |
|
-AA35-BT1 |
Outside sensor |
Included in SMO 20 |
||
-AA35-BT6 |
Controlling hot water sensor |
Included in SMO 20 |
||
-AA35-BT7 |
Display hot water sensor |
Included in SMO 20 |
||
-AA35-BT25 |
External supply temperature sensor |
Included in SMO 20 |
||
-AA35-BT63 |
External supply temperature sensor before QN10 |
Included in SMO 20 |
||
-AA35-BT71 |
External return line sensor |
Included in SMO 20 |
||
-FL10 |
Safety valve, heating medium |
|||
-AA35-GP10 |
External heating medium pump |
|||
-AA35-GP12 |
Charge pump for EB101 |
NIBE CPD 11 |
067 321 / 067 320 |
|
-AA35-GP12.1 |
Charge pump for EB101 |
NIBE CPD 11 |
067 321 / 067 320 |
|
-AA35-GP12.2 |
Charge pump for EB102 |
NIBE CPD 11 |
067 321 / 067 320 |
|
-AA35-GP12.3 |
Charge pump for EB103 |
NIBE CPD 11 |
067 321 / 067 320 |
|
-AA35-GP12.4 |
Charge pump for EB104 |
NIBE CPD 11 |
067 321 / 067 320 |
|
-AA35-GP12.5 |
Charge pump for EB105 |
NIBE CPD 11 |
067 321 / 067 320 |
|
-AA35-QN10 |
Reversing valve, heating/hot water |
See the valve’s manual for a port description. |
||
-AA35-QN43 |
Bypass valve, cooling operation |
|||
-EB100 |
Heat pump system |
NIBE SMO 20 |
||
-EB100F1355 |
Heat pump system |
? |
||
-EB100F1330 |
Heat pump system |
S2125/F2120/F2040 |
||
-EB100F1360 |
Heat pump system |
S2125/F2120/F2040 |
||
-EP14 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
||
-EP15 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
||
-EB100-BT1 |
Outside sensor |
Included in SMO 20 |
||
-BT1 |
Outside sensor |
Included in SMO 20 |
||
-BT6 |
Controlling hot water sensor |
Included in SMO 20 |
||
-EB100-BT6 |
Controlling hot water sensor |
Included in SMO 20 |
||
-EB100-BT7 |
Display hot water sensor |
Included in SMO 20 |
||
-BT7 |
Display hot water sensor |
Included in SMO 20 |
||
-EB100-BT25 |
External supply temperature sensor |
|||
-BT25 |
External supply temperature sensor |
|||
-EB100-BT71 |
External return line sensor |
|||
-BT71 |
External return line sensor |
|||
-EB100-CM4 |
Expansion vessel, hot water |
Included in SMO 20 |
||
-EB100-FL1 |
Safety valve, hot water |
Included in SMO 20 |
||
-EB100-FL5 |
T&P valve |
Included in SMO 20 |
||
-EB100-FL6 |
Vacuum valve |
Included in SMO 20 |
||
-EB100-FQ1 |
Mixing valve |
Included in SMO 20 |
||
-EB100-QN17 |
Pressure reduction valve |
Included in SMO 20 |
||
-EB100-QM30 |
Shut-off valve |
|||
-EB100-RM1 |
Non-return valve |
|||
-EB100-WM3.1 |
Tundish, cold water |
Included in SMO 20 |
||
-EB100-WM3.2 |
Tundish, T&P valve |
Included in SMO 20 |
||
-EB100-GP7 |
External brine pump |
|||
-EB100-GP10 |
External heating medium pump |
|||
-GP10 |
External heating medium pump |
|||
-EB100-QN10 |
Reversing valve, heating/hot water |
See the valve’s manual for a port description. |
||
-QN10 |
Reversing valve, heating/hot water |
See the valve’s manual for a port description. |
||
-EP4 |
Heat exchanger, groundwater |
|||
-FL3 |
Safety valve, brine |
Included in SMO 20 |
||
-FL3 |
Safety valve, brine |
Included in SMO 20 |
||
-FL311xx |
Safety valve, brine |
Included in ?/S2125/F2120/F2040/SMO 20 |
||
-FL10-0 |
Safety valve, brine |
|||
-FL11-0 |
Safety valve, brine |
|||
-FL12-0 |
Safety valve, heating medium |
|||
-FL13-0 |
Safety valve, heating medium |
|||
-HQ1-F1360 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ1-F1330 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ2-F1360 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ2-F1330 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ3-F1360 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-HQ3-F1330 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-HQ4-F1360 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-HQ4-F1330 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-GP16-0 |
Circulation pump, brine |
Included in S2125/F2120/F2040 40/60 |
||
-QN11 |
Shuttle valve |
|||
-QM12 |
Filling valve, brine |
|||
-QM21 |
Vent valve, brine |
|||
-QM31 |
Shut-off valve, heating medium supply line |
|||
-QM32 |
Shut-off valve, heating medium return line |
|||
-QM33 |
Shut-off valve, brine in |
|||
-QM34 |
Shut off valve, brine out |
|||
-QM40 |
Shut-off valve |
|||
-QM42 |
Shut-off valve, brine in |
|||
-QM50-0 |
Shut off valve, brine |
|||
-QM51-0 |
Shut off valve, brine |
|||
-QM52-0 |
Shut off valve, brine |
|||
-QM53-0 |
Shut off valve, brine |
|||
-QM54-0 |
Shut-off valve, heating medium |
|||
-QM55-0 |
Shut-off valve, heating medium |
|||
-QM56-0 |
Shut-off valve, heating medium |
|||
-QM57-0 |
Shut-off valve, heating medium |
|||
-QZ2 |
Filterball, heating medium |
Included in ? |
The S2125/F2120/F2040 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2.1-0 |
Filterball, heating medium |
Included in ? |
||
-QZ2.2-0 |
Filterball, heating medium |
Included in ? |
||
-QZ2.3-0 |
Filterball, heating medium |
Included in ? |
||
-QZ2.4-0 |
Filterball, heating medium |
Included in ? |
||
-QZ3 |
Filterball, brine |
Included in ? |
The S2125/F2120/F2040 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ4 |
Filterball, heating medium |
Included in ? |
The S2125/F2120/F2040 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ5 |
Filterball, heating medium |
Included in ? |
The S2125/F2120/F2040 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-RM10-F1360 |
Non-return valve |
|||
-RM10-F1330 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM10-F1355 |
Non-return valve |
Included in ? |
||
-RM11-F1360 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM11-F1330 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM11-F1355 |
Non-return valve |
Included in ? |
||
-RM12-F1360 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM12-F1330 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM12-F1355 |
Non-return valve |
Included in ? |
||
-RM13-F1360 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM13-F1330 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM13-F1355 |
Non-return valve |
Included in ? |
||
-RN20 |
Trim valve |
|||
-RN21 |
Trim valve |
|||
-EB10011xx |
Heat pump system (master unit) |
? |
||
-EB10012xx |
Heat pump system (master unit) |
S2125/F2120/F2040 |
||
-EB10013xx |
Heat pump system (master unit) |
S2125/F2120/F2040 |
||
-BT111xx |
Outside sensor |
Included in ? |
||
-BT112xx |
Outside sensor |
Included in S2125/F2120/F2040 |
||
-BT113xx |
Outside sensor |
Included in S2125/F2120/F2040 |
||
-QZ311xx |
Filterball, brine |
Included in ? |
||
-QZ312xx |
Filterball, brine |
Included in S2125/F2120/F2040 |
||
-EB100-BT2511xx |
External supply temperature sensor |
Included in ?/SMO 20 |
||
-EB100-BT7111xx |
External return line sensor |
Included in ?/SMO 20 |
||
-EB100-QZ211xx |
Filterball, heating medium |
Included in ? |
||
-EB100-QZ212xx |
Filterball, heating medium |
Included in S2125/F2120/F2040 |
||
-EB101 |
Heat pump |
S2125/F2120/F2050/F2040 |
||
-GP16-1 |
Circulation pump, brine |
Included in S2125/F2120/F2040 40/60 |
||
-EB101-FL10 |
Safety valve, heating medium |
|||
-FL10-1 |
Safety valve, brine |
|||
-FL11-1 |
Safety valve, brine |
|||
-FL12-1 |
Safety valve, heating medium |
|||
-FL13-1 |
Safety valve, heating medium |
|||
-HQ1-1361 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ1-F1330-1 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ2-1362 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ2-F1330-1 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ3-1362 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-HQ3-F1330-1 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-HQ4-1362 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-HQ4-F1330-1 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-EB101-QM1 |
Drain valve, heating medium |
|||
-EB101-QM40 |
Shut-off valve, heating medium |
|||
-QM50-1 |
Shut off valve, brine |
|||
-QM51-1 |
Shut off valve, brine |
|||
-QM52-1 |
Shut off valve, brine |
|||
-QM53-1 |
Shut off valve, brine |
|||
-QM54-1 |
Shut-off valve, heating medium |
|||
-QM55-1 |
Shut-off valve, heating medium |
|||
-QM56-1 |
Shut-off valve, heating medium |
|||
-QM57-1 |
Shut-off valve, heating medium |
|||
-EB101-QZ2 |
Filterball, heating medium |
Included in S2125/F2120/F2050/F2040 |
||
-QZ2.1-1 |
Filterball, brine |
Included in ? |
||
-QZ2.2-1 |
Filterball, brine |
Included in ? |
||
-QZ2.3-1 |
Filterball, heating medium |
Included in ? |
||
-QZ2.4-1 |
Filterball, heating medium |
Included in ? |
||
-EB101-RM1 |
Non-return valve, heating medium |
|||
-RM10-F1361 |
Non-return valve |
|||
-RM10-F1330-1 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM10-F1355-1 |
Non-return valve |
Included in ? |
||
-RM11-F1361 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM11-F1330-1 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM11-F1355-1 |
Non-return valve |
Included in ? |
||
-RM12-F1361 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM12-F1330-1 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM12-F1355-1 |
Non-return valve |
Included in ? |
||
-RM13-F1361 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM13-F1330-1 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM13-F1355-1 |
Non-return valve |
Included in ? |
||
-EB102 |
Heat pump 2 |
S2125/F2120/F2040 |
||
-GP16-2 |
Circulation pump, brine |
Included in S2125/F2120/F2040 40/60 |
||
-EB102-FL10 |
Safety valve, heating medium |
|||
-FL10-2 |
Safety valve, brine |
|||
-FL11-2 |
Safety valve, brine |
|||
-FL12-2 |
Safety valve, heating medium |
|||
-FL13-2 |
Safety valve, heating medium |
|||
-HQ1-F1362 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ1-F1330-2 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ2-F1362 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ2-F1330-2 |
Particle filter, brine |
Included in S2125/F2120/F2040 |
||
-HQ3-F1362 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-HQ3-F1330-2 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-HQ4-F1362 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-HQ4-F1330-2 |
Particle filter, heating medium |
Included in S2125/F2120/F2040 |
||
-EB102-QM1 |
Drain valve, heating medium |
|||
-EB102-QM40 |
Shut-off valve, heating medium |
|||
-QM50-2 |
Shut off valve, brine |
|||
-QM51-2 |
Shut off valve, brine |
|||
-QM52-2 |
Shut off valve, brine |
|||
-QM53-2 |
Shut off valve, brine |
|||
-QM54-2 |
Shut-off valve, heating medium |
|||
-QM55-2 |
Shut-off valve, heating medium |
|||
-QM56-2 |
Shut-off valve, heating medium |
|||
-QM57-2 |
Shut-off valve, heating medium |
|||
-QZ2.1-2 |
Filterball, brine |
Included in ? |
||
-QZ2.2-2 |
Filterball, brine |
Included in ? |
||
-QZ2.3-2 |
Filterball, heating medium |
Included in ? |
||
-QZ2.4-2 |
Filterball, heating medium |
Included in ? |
||
-RM10-F1362 |
Non-return valve |
|||
-RM10-F1330-2 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM10-F1355-2 |
Non-return valve |
Included in ? |
||
-RM11-F1362 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM11-F1330-2 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM11-F1355-2 |
Non-return valve |
Included in ? |
||
-RM12-F1362 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM12-F1330-2 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM12-F1355-2 |
Non-return valve |
Included in ? |
||
-RM13-F1362 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM13-F1330-2 |
Non-return valve |
Included in S2125/F2120/F2040 |
||
-RM13-F1355-2 |
Non-return valve |
Included in ? |
||
-EB103 |
Heat pump 3 |
S2125/F2120/F2040 |
||
-EB103-AA25 |
AXC module |
Included in NIBE AXC 30 |
067 304 |
|
-EB103-FL10 |
Safety valve, heating medium |
|||
-EB103-QM1 |
Drain valve, heating medium |
|||
-EB103-QM40 |
Shut-off valve, heating medium |
|||
-EB104 |
Heat pump 4 |
S2125/F2120/F2040 |
||
-EB104-FL10 |
Safety valve, heating medium |
|||
-EB104-QM1 |
Drain valve, heating medium |
|||
-EB104-QM40 |
Shut-off valve, heating medium |
|||
-EB105 |
Heat pump 5 |
S2125/F2120/F2040 |
||
-EB105-AA25 |
AXC module |
Included in NIBE AXC 30 |
067 304 |
|
-EB105-FL10 |
Safety valve, heating medium |
|||
-EB105-QM1 |
Drain valve, heating medium |
|||
-EB105-QM40 |
Shut-off valve, heating medium |
|||
XL1 |
Heating medium connection, supply |
|||
XL2 |
Heating medium connection, return |
|||
0.1 |
Ventilation unit 1 |
|||
-RN1 |
Trim valve |
|||
-AZ11 |
Ventilation module |
|||
0 |
Exhaust air module |
NIBE F135 |
067 075 |
|
0 |
Exhaust air module |
NIBE S135 |
067 075 |
|
-AZ30 |
Ventilation unit |
NIBE ERS |
||
-CL11 |
Pool system |
|||
-CL11-AA25 |
AXC module, pool |
|||
-CL11-BT25 |
External supply temperature sensor |
|||
-CL11-BT51 |
Pool sensor |
|||
-CL11-EP5 |
Exchanger, pool |
|||
-CL11-GP9 |
Circulation pump, pool |
|||
-CL11-HQ4 |
Particle filter, pool |
|||
-CL11-QN19 |
Three way valve, pool |
See the valve’s manual for a port description. |
||
-CL11-RM1 |
Non-return valve, pool |
|||
-CL12 |
Pool system 2 |
|||
-CL12-AA25 |
AXC module, pool |
|||
-CL12-BT25 |
External supply temperature sensor |
|||
-CL12-BT51 |
Pool sensor |
|||
-CL12-EP5 |
Exchanger, pool |
|||
-CL12-GP9 |
Circulation pump, pool |
|||
-CL12-GP12 |
Charge pump, pool |
Included in POOL 310 |
||
-CL12-HQ4 |
Particle filter, pool |
|||
-CL12-QN19 |
Three way valve, pool |
See the valve’s manual for a port description. |
||
-CP1 |
Storage tank |
|||
-CP1.1 |
Storage tank |
|||
-CP1.1-CM4 |
Expansion vessel, hot water |
Included in accumulator tank |
||
-CP1-CM4 |
Expansion vessel, hot water |
Included in accumulator tank |
||
-CP1.1-FL1 |
Safety valve, hot water |
|||
-CP1-FL1 |
Safety valve, hot water |
|||
-CP1.1-FL5 |
T&P valve |
Included in accumulator tank |
||
-CP1.2-FL5 |
T&P valve |
Included in accumulator tank |
||
-CP1-FL5 |
T&P valve |
Included in accumulator tank |
||
-CP1.1-FL6 |
Vacuum valve |
Included in accumulator tank |
||
-CP1.2-FL6 |
Vacuum valve |
Included in accumulator tank |
||
-CP1-FL6 |
Vacuum valve |
Included in accumulator tank |
||
-CP1.1-FQ1 |
Thermal mixing valve |
|||
-CP1-FQ1 |
Thermal mixing valve |
|||
-CP1.1-QN17 |
Pressure reduction valve |
Included in accumulator tank |
||
-CP1-QN17 |
Pressure reduction valve |
Included in accumulator tank |
||
-CP1.1-QM30 |
Shut-off valve |
|||
-CP1-QM30 |
Shut-off valve |
|||
-CP1.1-QM40 |
Shut off valve |
Included in accumulator tank |
||
-CP1.2-QM40 |
Shut off valve |
Included in accumulator tank |
||
-CP1.1-RM1 |
Non-return valve |
|||
-CP1-RM1 |
Non-return valve |
|||
-CP1.1-WM3.1 |
Tundish, cold water |
Included in accumulator tank |
||
-CP1-WM3.1 |
Tundish, cold water |
Included in accumulator tank |
||
-CP1.1-WM3.2 |
Tundish, T&P valve |
Included in accumulator tank |
||
-CP1.2-WM3.2 |
Tundish, T&P valve |
Included in accumulator tank |
||
-CP1-WM3.2 |
Tundish, T&P valve |
Included in accumulator tank |
||
-CP1.1-RN1.1 |
Trim valve |
|||
-CP1-RN1.1 |
Trim valve |
|||
-CP1-RN1 |
Trim valve |
|||
-CP1.1-RN1.2 |
Trim valve |
|||
-CP1-RN1.2 |
Trim valve |
|||
-CP1.2 |
Storage tank |
|||
-CP1.2-RN1.1 |
Trim valve |
|||
-CP1.2-RN1.2 |
Trim valve |
|||
-RN60 |
Trim valve |
|||
-RN61 |
Trim valve |
|||
-CP2 |
Water heater |
|||
-CP2-FQ1 |
Thermal mixing valve |
Part no. 624 922 |
||
-CP4 |
Additional water heater |
|||
-CP10.4 |
Tanks |
|||
-CP10.4 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-CP10.5 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-CP10.6 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-CP10.7 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-EB1 |
Step-controlled additional heat/electric boiler |
|||
-EB1-BT25 |
Supply temperature sensor, heating medium, external |
Included in NIBE AXC 30 |
||
-EB1-BT52 |
Boiler sensor |
Included in NIBE AXC 30 |
||
-EB1-CM5 |
Closed expansion vessel, heating medium |
|||
-EB1-EP7 |
District heating exchanger |
|||
-EB1-FL2 |
Safety valve, heating medium |
|||
-EB1-GP10 |
Circulation pump, heating medium external |
|||
-EB1-QM40 |
Shut-off valve |
|||
-EB1-QM41 |
Shut-off valve |
|||
-EB1-QN11 |
Shuttle valve |
See the valve’s manual for a port description. |
||
-EB1-RM5 |
Non-return valve |
|||
-RN1 |
Trim valve |
|||
-EB2 |
External electrical backup |
|||
-EB3 |
Immersion heater in tank |
with junction box K11 |
IU 3 kW: 218 009 IU 6 kW: 218 011 IU 9 kW: 218 003 018 893 |
|
-EB3-QA1 |
Auxiliary relay |
HR 10 |
067 309 |
|
-EB15 |
Indoor module |
SMO 20 |
||
-EB15-BT1 |
Outside sensor |
Included in SMO 20 |
||
-EB15-BT25 |
External supply temperature sensor |
Included in NIBE AXC 30 |
||
-EB15-BT25_extcp |
External supply temperature sensor |
|||
-EB15-CM4 |
Expansion vessel, hot water |
|||
-EB15-GP10 |
Circulation pump, heating medium external |
|||
-EB15-FL1 |
Safety valve, hot water |
|||
-EB15-RM2 |
Non-return valve |
|||
-EB15-QM30 |
Shut-off valve, hot water |
|||
-EB15-WM4 |
Tundish, T&P valve |
Included in SMO 20 |
||
XL |
XL connections |
|||
1 |
Heating medium connection, supply |
|||
2 |
Heating medium connection, return |
|||
3 |
Cold water connection |
|||
4 |
Hot water connection |
|||
5 |
Hot water circulation connection |
|||
6 |
Brine connection, supply |
|||
7 |
Brine connection, return |
|||
8 |
Docking connection, supply (from heat pump) |
|||
9 |
Docking connection, return (to heat pump) |
|||
13 |
Solar heat connection, supply |
|||
14 |
Solar heat connection, return |
|||
18 |
Docking connection, supply (high temp) |
|||
19 |
Docking connection, return (high temp) |
|||
29 |
T&Pvalve |
|||
30 |
Expansion vessel connection |
|||
36 |
Heating medium connection, supply |
|||
37 |
Heating medium connection, return |
|||
39 |
Docking connection, pool |
|||
-EM1 |
Shunt controlled additional heat |
|||
-EM1-QN11 |
Shunt valve for additional heat |
|||
-EM1-BT52 |
Boiler sensor |
Included in NIBE AXC 30 |
||
-EM1-BT25 |
Supply temperature sensor, heating medium, external |
Included in NIBE AXC 30 |
||
-EM1-GP10 |
External heating medium pump |
|||
-EM1/EB1 |
Electric boiler, wood boiler, pellet boiler, oil boiler or district heating |
|||
-EM1/EB1-GP10 |
Circulation pump |
|||
-EP1 |
District heating |
|||
-EP1-AA25 |
AXC module |
Included in NIBE AXC 30 |
067 060 |
|
-EP1-BT25 |
External supply temperature sensor |
Included in NIBE AXC 30 |
||
-EP1-BT52 |
Boiler sensor |
Included in SMO 20 |
||
-EP1-CM5 |
Closed expansion vessel, heating medium |
|||
-EP1-EP3 |
District heating exchanger, hot water |
|||
-EP1-EP7 |
District heating exchanger |
|||
-EP1-FL2 |
Safety valve, heating medium |
|||
-EP1-QN11 |
Mixing valve, addition |
See the valve’s manual for a port description. |
||
-EP1-RM1 |
Non-return valve |
|||
-EP1-CT1 |
District heating |
Cetetherm Mini Plus VP / Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP1-CT2 |
District heating |
Cetetherm Mini Plus VP / Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP1-CT3 |
District heating |
Cetetherm Mini Plus VP / Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP1-QM40 |
Shut off valve |
|||
-EP10 |
Shunt controlled brine |
|||
-EP10-AA25 |
AXC module |
Included in NIBE AXC 30 |
067 060 |
|
-EP10-BT26 |
Temperature sensor, brine in |
Included in NIBE AXC 30 |
||
-EP10-QN41 |
Shunt valve, brine |
See the valve’s manual for a port description. |
||
-EP10-EP10 |
Heat exchanger |
|||
-EP12 |
Ground water system |
|||
-EP12-AA25 |
AXC module, groundwater |
Included in NIBE AXC 30 |
067 060 |
|
-EP12-EP4 |
Groundwater exchanger |
|||
-EP12-GP3 |
Circulation pump, groundwater |
|||
-EP12-HQ40 |
Particle filter, groundwater |
|||
-EP21-RM1 |
Non-return valve |
|||
-EP22 |
Heating system 3 |
NIBE AXC 30 |
067 287 / 067 288 |
|
K |
Climate system 3 |
NIBE AXC 30 |
067 304 |
|
-EP22-AA25 |
AXC module, heating system 3 |
Included in NIBE AXC 30 |
||
-EP22-BT2 |
Supply temperature sensor, heating system 3 |
Included in NIBE AXC 30 |
||
-EP22-BT3 |
Return line sensor, heating system 3 |
Included in NIBE AXC 30 |
||
-EP22-GP10 |
Circulation pump, heating system 3 |
Included in NIBE AXC 30 |
||
-EP22-QN25 |
Shunt valve, heating system 3 |
Included in NIBE AXC 30 See the valve’s manual for a port description. |
||
-EP22-RM1 |
Non-return valve |
|||
-EP26 |
HRV unit |
ERS |
||
-EP30 |
Solar heating system |
SCA 35 |
067 245 |
|
-EP30-AA25 |
AXC module |
Included in SCA |
||
-EP8 |
Solar panels |
|||
-EP30-EP9 |
Exchanger, solar |
|||
-EP30-GP10 |
Circulation pump |
|||
-EP44-AA25 |
AXC module, cooling system 1 |
Included in Passiv |
||
-EP44-BT2 |
Supply temperature sensor, cooling system 1 |
|||
-EP44-BT3 |
Return line sensor, cooling system 1 |
|||
-EP44-BT64 |
Flow temperature sensor, cooling |
Included in Passiv |
||
-EP44-BT65 |
Return line sensor, cooling |
Included in Passiv |
||
-EP45 |
Cooling system 1 |
|||
-EP45-AA25 |
AXC module, cooling system 1 |
Included in NIBE AXC 30 |
067 060 |
|
-EP45-GP10 |
Circulation pump, cooling system 1 |
|||
-EP25 |
Passive cooling system |
Passiv |
067 296 |
|
-EP25-AA25 |
AXC module, cooling |
Included in Passiv |
||
-EP25-BT64 |
Temperature sensor, cooling flow line |
Included in Passiv |
||
-EP25-BT65 |
Temperature sensor, cooling return line |
Included in Passiv |
||
-EP25-EP13 |
Supply air coil/fan coil |
|||
-EP25-GP13 |
Circulation pump, cooling |
Included in Passiv |
||
-EP25-QN18 |
Mixing valve, cooling |
Included in Passiv See the valve’s manual for a port description. |
||
-EP25-RM1 |
Non-return valve |
|||
-EQ1-AA25 |
AXC module, cooling |
Included in NIBE AXC 30 |
||
-EQ1-BP6 |
Pressure gauge, brine |
|||
-EQ1-BT57 |
Temperature sensor, collector |
Included in NIBE AXC 30 |
||
-EQ1-BT64 |
Flow temperature sensor, cooling |
|||
-EQ1-BT75 |
Temperature sensor, flow line after heat dump |
Included in NIBE AXC 30 |
||
-EQ1-CM3 |
Expansion vessel, brine |
|||
-EQ1-EP6 |
Heat exchanger |
|||
-EQ1-EP18 |
Coolant radiator |
|||
-EQ1-FL3 |
Safety valve, brine |
|||
-EQ1-GP10 |
Circulation pump |
|||
-EQ1-GP12 |
Circulation pump |
Included in NIBE AXC 30 |
||
-EQ1-GP14 |
Circulation pump for heat dump |
|||
-EQ1-GP20 |
Circulation pump, heat dump |
|||
-EQ1-QM40.1 |
Shut-off valve |
|||
-EQ1-QM40.2 |
Shut-off valve |
|||
-EQ1-QN12 |
Reversing valve, cooling |
See the valve’s manual for a port description. |
||
-EQ1-QN18 |
Shunt valve, cooling shunt |
See the valve’s manual for a port description. |
||
-EQ1-QN36 |
Shunt valve, heating shunt |
See the valve’s manual for a port description. |
||
-EQ1-RM1 |
Non-return valve, heat dump |
|||
-EQ1-RM2 |
Non-return valve, heat dump |
|||
-EQ1-RM3 |
Non-return valve, heat dump |
|||
-GC1 |
Solar panels |
NIBE PV |
||
-QZ1 |
Hot water circulation (HWC) |
|||
-QZ1-BT70 |
Supply temperature sensor, HWC |
Included in NIBE AXC 30 |
||
-QZ1-BT82 |
Return line sensor, HWC |
Included in NIBE AXC 30 |
||
-QZ1-FQ3 |
Mixer valve, HWC |
|||
-QZ1-GP11 |
Circulation pump, HWC |
|||
-QZ1-QN2 |
4-way valve, HWC |
See the valve’s manual for a port description. |
||
-QZ1-RM1 |
Non-return valve, HWC |
|||
-QZ1-RN1 |
Trim valve, HWC |
|||
-QZ1-RN4 |
Trim valve, HWC |
|||
-QZ20 |
Filling kit |
KB 25/ KB 32 |
KB 25 (max. 12 kW), KB 32 (max. 30 kW) |
|
-QM33 |
Shut off valve, brine flow |
|||
-XL27 |
Filling brine |
|||
-XL28 |
Filling brine |
|||
-FL2 |
Miscellaneous |
|||
-BP5 |
Pressure gauge, heating medium |
|||
-BP6 |
Pressure gauge, brine |
|||
-CM1 |
Expansion vessel, heating medium |
|||
-CM2 |
Level vessel, brine |
|||
-CM3 |
Expansion vessel, brine |
Expansion vessel in closed system |
||
-CM4 |
Expansion vessel, hot water |
Included in SMO 20 |
||
-CP10 |
Buffer vessel |
UKV |
Size varies depending on the dimensioning of hot water |
|
-CP10.1 |
Buffer vessel |
UKV |
Size varies depending on heat pump and system volume |
|
-CP10.2 |
Buffer vessel, cooling |
UKV |
Condensation-insulated vessels for cooling Size varies depending on heat pump and system volume |
|
-CP10.3 |
Buffer vessel |
UKV |
Size varies depending on the dimensioning of hot water |
|
-FL1 |
Safety valve, hot water |
|||
-FL2 |
Safety valve, heating medium |
|||
-FQ1 |
Mixing valve |
Thermal |
||
-RM1 |
Non-return valve |
|||
-RM1.1 |
Non-return valve |
|||
-RM1.2 |
Non-return valve |
|||
-RM1.3 |
Non-return valve |
|||
-RM2 |
Non-return valve |
|||
-RM3 |
Non-return valve |
|||
-RN1.1 |
Trim valve |
|||
-RN1.2 |
Trim valve |
|||
-RN1.3 |
Trim valve |
|||
-RN2.1 |
Trim valve |
|||
-RN2.2 |
Trim valve |
|||
-RN3.1 |
Trim valve |
|||
-RN3.2 |
Trim valve |
|||
-RN4.1 |
Trim valve |
|||
-RN4.2 |
Trim valve |
|||
-RN5.1 |
Trim valve |
|||
-RN5.2 |
Trim valve |
|||
-QM1 |
Drain valve, heating medium |
|||
-QM30 |
Shut-off valve, hot water |
|||
-QN17 |
Pressure reduction valve |
|||
-QN44 |
Shut off valve |
|||
-WM3 |
Tundish, cold water |
Included in SMO 20 |
||
-WM4 |
Tundish, T&P valve |
Included in SMO 20 |
Designations according to standard EN 81346-2.