Protective and safety equipment as well as components that facilitate servicing (e.g. non-return valves, safety valves, bypass valves, shut-off valves) must be installed in accordance with national regulations and standards. The installation must be dimensioned to cope with the minimum defrosting flow at 100% charge pump operation.
[Docking-ComponentNotesParagraph]
The compressor in a S2125/F2120/F2050 is inverter-controlled. The compressor’s power is adjusted according to the demand and it is routed to heating, hot water, cooling or pool heating.
The compressor in a F2300 is an on/off type. The compressor’s full power is routed to heating, hot water or pool heating.
In the case of multiple heat pumps, they are stepped in one-by-one as required.
SMO S40 is equipped with a heating control system, which means that the heating supply to the property takes place according to selected settings. For more information about heat production, see the Installer Manual.
If hot water heating is required, one or more external water heaters/accumulator tanks are docked.
Hot water production is from the heat pump(s) that are set to produce hot water.
If the hot water temperature exceeds 60 °C, the installation must be supplemented with a mixing valve.
For more information about hot water production, see the manual for SMO S40 and/or the water heater’s/accumulator tank’s manual.
An external heating medium pump can be connected via an AUX output in SMO S40. If the AUX output is being used for any other function, the heating medium pump can instead be connected via the AXC module. The heating medium pump can be connected via the following functions:
additional heat (accessory AXC 30)
shunt-controlled additional heat (accessory AXC 30)
An external brine pump can be connected via an AUX output in SMO S40. If the AUX output is being used for any other function, the brine pump can instead be connected via the AXC module. The brine pump can be connected via the following functions:
ground water pump (accessory AXC 30)
This function requires the AXC 30 accessory. Shunt valve, supply and return line sensors as well as circulation pump are connected to the extra climate system with a lower temperature demand. The temperature in the extra climate system is in accordance with the selected curve slope and offset setting.
Up to 8 extra climate systems can be connected to the installation.
For further information, see the Installer Manual for the accessory.
See the valve’s manual for a port description.
This function requires the AXC 30 accessory. Shunt valve, supply and return line sensors, as well as circulation pump, are connected to other heating circuits with a lower temperature demand (e.g. underfloor heating system). The temperature in the extra heating system follows the selected curve slope and offset setting. Up to 8 extra heating systems can be connected to the installation.
For further information, see the Installer Manual for the accessory.
See the valve’s manual for a port description.
For enhanced hot water.
Ventilation recovery means that the heat from the exhaust air is utilised and supplied to the installation.
For further information, see the Installer Manual for the accessory.
This connection enables the use of ground water as heat source. The ground water is pumped up to an intermediate heat exchanger. An intermediate heat exchanger is used to protect the heat pump's exchanger from dirt and freezing. The water is released into a buried filtration unit or a drilled well.
The ground water pump runs at the same time as the brine pump.
Cooling and heating are distributed via the same climate system.
When there is a risk of condensation, components and climate systems must be insulated against condensation in accordance with current standards and provisions, or the min. supply temperature must be limited.
With the accessory AXC 30, separate cooling and heating systems can be connected via a reversing valve. The cooling system is connected after the heat pump. When cooling is required (activated from the outdoor temperature sensor AA35-BT1 and room sensor AA35-BT50, where applicable), the shunt valve EQ1-QN12 and the circulation pump AA35-GP12 are activated.
See the valve’s manual for a port description.
With the AXC 30 accessory, the heat pump(s) can be used to heat one or more pools.
For further information, see the Installer Manual for the accessory.
During pool operation and hot water production, you can choose which of the heat pumps will be responsible for operation. More heat pump selections can be made.
SMO S40 can control step-controlled additional heat via a control signal.
The additional heat is used for heat production.
For further information, see the Installer Manual for the accessory.
This function enables step-controlled additional heat to help with heating/hot water production.
With SMO S40, three relays can be used for additional heat control, which then gives max. 3 linear or 7 binary steps.
The flow through the additional heat is ensured by the charge pump (GP12).
For more information about step-controlled additional heat, see the Installer Manual.
Used to produce hot water at the same time as the heat pump(s) prioritises other demands.
An immersion heater in a tank can also be used if a higher hot water temperature is required than can be produced by a heat pump.
SMO S40 can, via a control signal, control additional heat, which can also be prioritised.
The additional heat is used for heat production.
For further information, see the Installer Manual for the accessory.
This function enables district heating additional heat to assist with heating.
This function allows additional district heating to assist with the heating as shunt-controlled additional heat.
The AXC module AA25, external circulation pump GP10 and the sensors BT52, BT25 and BT71 are enclosed and are installed in the district heating module. The sensors BT25 and BT71 are connected to SMO S40.
The trim valve RN1 is used to regulate the flow over the heat pump and the district heating unit, and to avoid a high district heating return. Ensure the defrosting flow according to the Installer Manual.
This function enables district heating additional heat to produce both heat and hot water, including hot water circulation.
The AXC module AA25, external circulation pump GP10 and the sensors BT52, BT25 and BT71 are enclosed and are installed in the district heating module. The sensors BT25 and BT71 are connected to SMO S40.
The trim valve RN1 is used to regulate the flow over the heat pump and the district heating unit, and to avoid a high district heating return. Ensure the defrosting flow according to the Installer Manual.
An electric heater can be activated by the AUX output when the compressor is stopped by a low outdoor temperature. Max. recommended power is 4.5 kW.
For further information, see the Installer Manual for the accessory.
This connection makes it possible to control a shunt valve that regulates the incoming brine temperature.
The heat pump controls a shunt valve (QN41) to limit the maximum incoming brine temperature via temperature sensor (BT26). If the sensor registers a value above the maximum set temperature, the shunt valve is closed to reduce the mix of incoming brine.
The function is only active when the accessory AXC 30 is activated and when a compressor in the system is running.
A 2-pipe, parallel-connected buffer vessel is used for high-temperature and/or low-flow systems. This connection principle requires a continuous flow over the external supply temperature sensor (BT25) and it is used as a buffer for the heat pump (volume expansion) and as a buffer for the climate system (for large, temporary power outputs such as defrosting and fan coil, etc.).
For further information, see the Installer Manual for the accessory.
A 2-pipe, serially connected buffer vessel is used as a buffer for the heat pump (volume expansion and when there is a risk of short operating times). This connection principle requires a continuous flow over the external supply temperature sensor (BT25) and is used as a buffer for the heat pump (volume expansion) and as a buffer for the climate system (for large, temporary power outputs such as defrosting and fan coil, etc.).
For further information, see the Installer Manual for the accessory.
A circulation pump can be controlled by SMO S40 to circulate the hot water. The circulating water must have a temperature that prevents bacterial growth and scalding, and national standards must be satisfied. See the appropriate Installer Manual for more information.
Designation |
Name |
Specification |
Part No. |
Comments |
---|---|---|---|---|
-AA35 |
Control module |
SMO S40 |
067 225 |
|
-AA35-BT1 |
Outside sensor |
Included in SMO S40 Modbus: 1 (input) |
||
-AA35-BT6 |
Controlling hot water sensor |
Included in SMO S40 Modbus: 9 (input) |
||
-AA35-BT7 |
Display hot water sensor |
Included in SMO S40 Modbus: 8 (input) |
||
-AA35-BT25 |
External supply temperature sensor |
Included in SMO S40 Modbus: 39 (input) |
||
-AA35-BT63 |
External supply temperature sensor before QN10 |
Included in SMO S40 Modbus: 72 (input) |
||
-AA35-BT71 |
External return line sensor |
Included in SMO S40 Modbus: 88 (input) |
||
-FL10 |
Safety valve, heating medium |
|||
-AA35-GP10 |
External heating medium pump |
Modbus: 1825 |
||
-AA35-GP12 |
Charge pump for EB101 |
NIBE CPD 11 Modbus: 1636 (input) |
067 321 / 067 320 |
|
-AA35-GP12.1 |
Charge pump for EB101 |
NIBE CPD 11 Modbus: 1636 (input) |
067 321 / 067 320 |
|
-AA35-GP12.2 |
Charge pump for EB102 |
NIBE CPD 11 Modbus: 1635 (input) |
067 321 / 067 320 |
|
-AA35-GP12.3 |
Charge pump for EB103 |
NIBE CPD 11 Modbus: 1634 (input) |
067 321 / 067 320 |
|
-AA35-GP12.4 |
Charge pump for EB104 |
NIBE CPD 11 Modbus: 1633 (input) |
067 321 / 067 320 |
|
-AA35-GP12.5 |
Charge pump for EB105 |
NIBE CPD 11 Modbus: 1633 (input) |
067 321 / 067 320 |
|
-AA35-QN10 |
Reversing valve, heating/hot water |
See the valve’s manual for a port description. |
089 152 / 089 388 |
VST 11 (max. 17 kW), VST 20 (max. 40 kW) |
-AA35-QN43 |
Bypass valve, cooling operation |
|||
-EB100 |
Heat pump system |
NIBE SMO S40 |
||
-EB100F1355 |
Heat pump system |
? |
||
-EB100F1330 |
Heat pump system |
S2125/F2120/F2050 |
||
-EB100F1360 |
Heat pump system |
S2125/F2120/F2050 |
||
-EP14 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
||
-EP15 |
Cooling module |
See the Installer Manual for more information about the relevant cooling module. |
||
-EB100-BT1 |
Outside sensor |
Included in SMO S40 Modbus: 1 (input) |
||
-BT1 |
Outside sensor |
Included in SMO S40 Modbus: 1 (input) |
||
-BT6 |
Controlling hot water sensor |
Included in SMO S40 Modbus: 9 (input) |
||
-EB100-BT6 |
Controlling hot water sensor |
Included in SMO S40 Modbus: 9 (input) |
||
-EB100-BT7 |
Display hot water sensor |
Included in SMO S40 Modbus: 8 (input) |
||
-BT7 |
Display hot water sensor |
Included in SMO S40 Modbus: 8 (input) |
||
-EB100-BT25 |
External supply temperature sensor |
Modbus: 39 (input) |
||
-BT25 |
External supply temperature sensor |
Modbus: 39 (input) |
||
-EB100-BT71 |
External return line sensor |
Modbus: 88 (input) |
||
-BT71 |
External return line sensor |
Modbus: 88 (input) |
||
-EB100-CM4 |
Expansion vessel, hot water |
Included in SMO S40 |
||
-EB100-FL1 |
Safety valve, hot water |
Included in SMO S40 |
||
-EB100-FL5 |
T&P valve |
Included in SMO S40 |
||
-EB100-FL6 |
Vacuum valve |
Included in SMO S40 |
||
-EB100-FQ1 |
Mixing valve |
Included in SMO S40 |
||
-EB100-QN17 |
Pressure reduction valve |
Included in SMO S40 |
||
-EB100-QM30 |
Shut-off valve |
|||
-EB100-RM1 |
Non-return valve |
|||
-EB100-WM3.1 |
Tundish, cold water |
Included in SMO S40 |
||
-EB100-WM3.2 |
Tundish, T&P valve |
Included in SMO S40 |
||
-EB100-GP7 |
External brine pump |
|||
-EB100-GP10 |
External heating medium pump |
Modbus: 1825 |
||
-GP10 |
External heating medium pump |
Modbus: 1825 |
||
-EB100-QN10 |
Reversing valve, heating/hot water |
See the valve’s manual for a port description. |
||
-QN10 |
Reversing valve, heating/hot water |
See the valve’s manual for a port description. |
||
-EP4 |
Heat exchanger, groundwater |
|||
-FL3 |
Safety valve, brine |
Included in SMO S40 |
||
-FL311xx |
Safety valve, brine |
Included in ?/S2125/F2120/F2050/SMO S40 |
||
-FL10-0 |
Safety valve, brine |
|||
-FL11-0 |
Safety valve, brine |
|||
-FL12-0 |
Safety valve, heating medium |
|||
-FL13-0 |
Safety valve, heating medium |
|||
-HQ1-F1360 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ1-F1330 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ2-F1360 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ2-F1330 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ3-F1360 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-HQ3-F1330 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-HQ4-F1360 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-HQ4-F1330 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-GP16-0 |
Circulation pump, brine |
Included in ? 40/60 |
||
-QN11 |
Shuttle valve |
|||
-QM12 |
Filling valve, brine |
|||
-QM21 |
Vent valve, brine |
|||
-QM31 |
Shut-off valve, heating medium supply line |
|||
-QM32 |
Shut-off valve, heating medium return line |
|||
-QM33 |
Shut-off valve, brine in |
|||
-QM34 |
Shut off valve, brine out |
|||
-QM40 |
Shut-off valve |
|||
-QM42 |
Shut-off valve, brine in |
|||
-QM50-0 |
Shut off valve, brine |
|||
-QM51-0 |
Shut off valve, brine |
|||
-QM52-0 |
Shut off valve, brine |
|||
-QM53-0 |
Shut off valve, brine |
|||
-QM54-0 |
Shut-off valve, heating medium |
|||
-QM55-0 |
Shut-off valve, heating medium |
|||
-QM56-0 |
Shut-off valve, heating medium |
|||
-QM57-0 |
Shut-off valve, heating medium |
|||
-QZ2 |
Filterball, heating medium |
Included in ? |
||
-QZ2.1-0 |
Filterball, heating medium |
Included in ? |
||
-QZ2.2-0 |
Filterball, heating medium |
Included in ? |
||
-QZ2.3-0 |
Filterball, heating medium |
Included in ? |
||
-QZ2.4-0 |
Filterball, heating medium |
Included in ? |
||
-QZ3 |
Filterball, brine |
Included in ? |
||
-QZ4 |
Filterball, heating medium |
Included in ? |
||
-QZ5 |
Filterball, heating medium |
Included in ? |
||
-RM10-F1360 |
Non-return valve |
|||
-RM10-F1330 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM10-F1355 |
Non-return valve |
Included in ? |
||
-RM11-F1360 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM11-F1330 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM11-F1355 |
Non-return valve |
Included in ? |
||
-RM12-F1360 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM12-F1330 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM12-F1355 |
Non-return valve |
Included in ? |
||
-RM13-F1360 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM13-F1330 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM13-F1355 |
Non-return valve |
Included in ? |
||
-RN20 |
Trim valve |
|||
-RN21 |
Trim valve |
|||
-EB10011xx |
Heat pump system (master unit) |
? |
||
-EB10012xx |
Heat pump system (master unit) |
S2125/F2120/F2050 |
||
-EB10013xx |
Heat pump system (master unit) |
S2125/F2120/F2050 |
||
-BT111xx |
Outside sensor |
Included in ? Modbus: 1 (input) |
||
-BT112xx |
Outside sensor |
Included in S2125/F2120/F2050 Modbus: 1 (input) |
||
-BT113xx |
Outside sensor |
Included in S2125/F2120/F2050 Modbus: 1 (input) |
||
-QZ311xx |
Filterball, brine |
Included in ? |
||
-QZ312xx |
Filterball, brine |
Included in S2125/F2120/F2050 |
||
-EB100-BT2511xx |
External supply temperature sensor |
Included in ?/SMO S40 Modbus: 39 (input) |
||
-EB100-BT7111xx |
External return line sensor |
Included in ?/SMO S40 Modbus: 88 (input) |
||
-EB100-QZ211xx |
Filterball, heating medium |
Included in ? |
||
-EB100-QZ212xx |
Filterball, heating medium |
Included in S2125/F2120/F2050 |
||
-EB101 |
Heat pump |
S2125/F2120/F2050/F2300 |
||
-GP16-1 |
Circulation pump, brine |
Included in ? 40/60 |
||
-EB101-EZ101 |
Outdoor module |
AMS |
||
-EB101-EZ102 |
SPLIT box |
HBS |
||
-EB101-FL10 |
Safety valve, heating medium |
|||
-FL10-1 |
Safety valve, brine |
|||
-FL11-1 |
Safety valve, brine |
|||
-FL12-1 |
Safety valve, heating medium |
|||
-FL13-1 |
Safety valve, heating medium |
|||
-HQ1-1361 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ1-F1330-1 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ2-1362 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ2-F1330-1 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ3-1362 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-HQ3-F1330-1 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-HQ4-1362 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-HQ4-F1330-1 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-EB101-HQ8 |
Gas separator |
Included in S2125 |
||
-EB101-QM1 |
Drain valve, heating medium |
|||
-EB101-QM40 |
Shut-off valve, heating medium |
|||
-QM50-1 |
Shut off valve, brine |
|||
-QM51-1 |
Shut off valve, brine |
|||
-QM52-1 |
Shut off valve, brine |
|||
-QM53-1 |
Shut off valve, brine |
|||
-QM54-1 |
Shut-off valve, heating medium |
|||
-QM55-1 |
Shut-off valve, heating medium |
|||
-QM56-1 |
Shut-off valve, heating medium |
|||
-QM57-1 |
Shut-off valve, heating medium |
|||
-EB101-QZ2 |
Filterball, heating medium |
Included in S2125/F2120/F2050 |
The F2300 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2.1-1 |
Filterball, brine |
Included in ? |
The S2125/F2120/F2050 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2.2-1 |
Filterball, brine |
Included in ? |
The S2125/F2120/F2050 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2.3-1 |
Filterball, heating medium |
Included in ? |
||
-QZ2.4-1 |
Filterball, heating medium |
Included in ? |
||
-EB101-RM1 |
Non-return valve, heating medium |
|||
-RM10-F1361 |
Non-return valve |
|||
-RM10-F1330-1 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM10-F1355-1 |
Non-return valve |
Included in ? |
||
-RM11-F1361 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM11-F1330-1 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM11-F1355-1 |
Non-return valve |
Included in ? |
||
-RM12-F1361 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM12-F1330-1 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM12-F1355-1 |
Non-return valve |
Included in ? |
||
-RM13-F1361 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM13-F1330-1 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM13-F1355-1 |
Non-return valve |
Included in ? |
||
-EB102 |
Heat pump 2 |
S2125/F2120/F2050/F2300 |
||
-GP16-2 |
Circulation pump, brine |
Included in ? 40/60 |
||
-EB102-FL10 |
Safety valve, heating medium |
|||
-FL10-2 |
Safety valve, brine |
|||
-FL11-2 |
Safety valve, brine |
|||
-FL12-2 |
Safety valve, heating medium |
|||
-FL13-2 |
Safety valve, heating medium |
|||
-HQ1-F1362 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ1-F1330-2 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ2-F1362 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ2-F1330-2 |
Particle filter, brine |
Included in S2125/F2120/F2050 |
||
-HQ3-F1362 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-HQ3-F1330-2 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-HQ4-F1362 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-HQ4-F1330-2 |
Particle filter, heating medium |
Included in S2125/F2120/F2050 |
||
-EB102-HQ8 |
Gas separator |
Included in S2125 |
||
-EB102-QM1 |
Drain valve, heating medium |
|||
-EB102-QM40 |
Shut-off valve, heating medium |
|||
-QM50-2 |
Shut off valve, brine |
|||
-QM51-2 |
Shut off valve, brine |
|||
-QM52-2 |
Shut off valve, brine |
|||
-QM53-2 |
Shut off valve, brine |
|||
-QM54-2 |
Shut-off valve, heating medium |
|||
-QM55-2 |
Shut-off valve, heating medium |
|||
-QM56-2 |
Shut-off valve, heating medium |
|||
-QM57-2 |
Shut-off valve, heating medium |
|||
-EB102-QZ2 |
Filterball, heating medium |
Included in S2125/F2120/F2050 |
The F2300 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2.1-2 |
Filterball, brine |
Included in ? |
The S2125/F2120/F2050 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2.2-2 |
Filterball, brine |
Included in ? |
The S2125/F2120/F2050 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-QZ2.3-2 |
Filterball, heating medium |
Included in ? |
||
-QZ2.4-2 |
Filterball, heating medium |
Included in ? |
||
-EB102-RM1 |
Non-return valve, heating medium |
|||
-RM10-F1362 |
Non-return valve |
|||
-RM10-F1330-2 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM10-F1355-2 |
Non-return valve |
Included in ? |
||
-RM11-F1362 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM11-F1330-2 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM11-F1355-2 |
Non-return valve |
Included in ? |
||
-RM12-F1362 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM12-F1330-2 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM12-F1355-2 |
Non-return valve |
Included in ? |
||
-RM13-F1362 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM13-F1330-2 |
Non-return valve |
Included in S2125/F2120/F2050 |
||
-RM13-F1355-2 |
Non-return valve |
Included in ? |
||
-EB103 |
Heat pump 3 |
S2125/F2120/F2050/F2300 |
||
-EB103-AA25 |
AXC module |
Included in AXC 30 |
067 304 |
|
-EB103-HQ8 |
Gas separator |
Included in S2125 |
||
-EB103-FL10 |
Safety valve, heating medium |
|||
-EB103-QM1 |
Drain valve, heating medium |
|||
-EB103-QM40 |
Shut-off valve, heating medium |
|||
-EB103-QZ2 |
Filterball, heating medium |
Included in S2125/F2120/F2050 |
The F2300 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-EB103-RM1 |
Non-return valve, heating medium |
|||
-EB104 |
Heat pump 4 |
S2125/F2120/F2050/F2300 |
||
-EB104-HQ8 |
Gas separator |
Included in S2125 |
||
-EB104-FL10 |
Safety valve, heating medium |
|||
-EB104-QM1 |
Drain valve, heating medium |
|||
-EB104-QM40 |
Shut-off valve, heating medium |
|||
-EB104-QZ2 |
Filterball, heating medium |
Included in S2125/F2120/F2050 |
The F2300 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-EB104-RM1 |
Non-return valve, heating medium |
|||
-EB105 |
Heat pump 5 |
S2125/F2120/F2050/F2300 |
||
-EB105-AA25 |
AXC module |
Included in AXC 30 |
067 304 |
|
-EB105-FL10 |
Safety valve, heating medium |
|||
-EB105-QM1 |
Drain valve, heating medium |
|||
-EB105-QM40 |
Shut-off valve, heating medium |
|||
-EB105-QZ2 |
Filterball, heating medium |
Included in S2125/F2120/F2050 |
The F2300 includes a particle filter, which should be supplemented with a shut-off valve. |
|
-EB105-RM1 |
Non-return valve, heating medium |
|||
XL1 |
Heating medium connection, supply |
|||
XL2 |
Heating medium connection, return |
|||
-AZ10.1 |
Ventilation unit 1 |
|||
-AZ10.1-GP2 |
Circulation pump, exhaust air recovery |
|||
-AZ10.1-RM20 |
Non-return valve, exhaust air recovery |
|||
-AZ10.1-RM1 |
Non-return valve, exhaust air recovery |
|||
-AZ10.1-RN1 |
Trim valve, exhaust air recovery |
|||
-RN1 |
Trim valve |
|||
-AZ10.2 |
Ventilation unit 2 |
|||
-AZ10.2-GP2 |
Circulation pump, exhaust air recovery |
|||
-AZ10.2-RM20 |
Non-return valve, exhaust air recovery |
|||
-AZ10.2-RM1 |
Non-return valve, exhaust air recovery |
|||
-AZ10.3 |
Ventilation unit 3 |
|||
-AZ10.3-GP2 |
Circulation pump, exhaust air recovery |
|||
-AZ10.3-RM20 |
Non-return valve, exhaust air recovery |
|||
-AZ10.3-RM1 |
Non-return valve, exhaust air recovery |
|||
-AZ11 |
Ventilation module |
|||
0 |
Exhaust air module |
NIBE F135 |
067 075 |
|
0 |
Exhaust air module |
NIBE S135 |
067 075 |
|
-AZ20_DWS |
Supply air module |
DWS |
067 872 |
|
-AZ20_SAM |
Supply air module |
SAM |
067 794 |
|
-AZ30 |
Ventilation unit |
NIBE ERS |
||
-CL11 |
Pool system |
AXC 30 |
067 304 |
|
-CL11-AA25 |
AXC module, pool |
Included in AXC 30 |
||
-CL11-BT25 |
External supply temperature sensor |
Modbus: 39 (input) |
||
-CL11-BT51 |
Pool sensor |
Included in AXC 30 Modbus: 27 (input) |
||
-CL11-EP5 |
Exchanger, pool |
|||
-CL11-GP9 |
Circulation pump, pool |
Modbus: 1828 (input) |
||
-CL11-GP12 |
Charge pump, pool |
Modbus: 1589 (input) |
||
-CL11-HQ4 |
Particle filter, pool |
|||
-CL11-QN19 |
Three way valve, pool |
Modbus: 1134 (input) See the valve’s manual for a port description. |
||
-CL11-RM1 |
Non-return valve, pool |
|||
-CL12 |
Pool system 2 |
AXC 30 |
067 304 |
|
-CL12-AA25 |
AXC module, pool |
Included in AXC 30 |
||
-CL12-BT25 |
External supply temperature sensor |
Modbus: 39 (input) |
||
-CL12-BT51 |
Pool sensor |
Included in AXC 30 Modbus: 27 (input) |
||
-CL12-EP5 |
Exchanger, pool |
|||
-CL12-GP9 |
Circulation pump, pool |
Modbus: 1827 (input) |
||
-CL12-GP12 |
Charge pump, pool |
Included in POOL 310 Modbus: 1589 (input) |
||
-CL12-HQ4 |
Particle filter, pool |
|||
-CL12-QN19 |
Three way valve, pool |
Modbus: 1134 (input) See the valve’s manual for a port description. |
||
-CP1 |
Storage tank |
|||
-CP1.1 |
Storage tank |
|||
-CP1.1-CM4 |
Expansion vessel, hot water |
Included in accumulator tank |
||
-CP1-CM4 |
Expansion vessel, hot water |
Included in accumulator tank |
||
-CP1.1-FL1 |
Safety valve, hot water |
|||
-CP1-FL1 |
Safety valve, hot water |
|||
-CP1.1-FL5 |
T&P valve |
Included in accumulator tank |
||
-CP1.2-FL5 |
T&P valve |
Included in accumulator tank |
||
-CP1-FL5 |
T&P valve |
Included in accumulator tank |
||
-CP1.1-FL6 |
Vacuum valve |
Included in accumulator tank |
||
-CP1.2-FL6 |
Vacuum valve |
Included in accumulator tank |
||
-CP1-FL6 |
Vacuum valve |
Included in accumulator tank |
||
-CP1.1-FQ1 |
Thermal mixing valve |
|||
-CP1-FQ1 |
Thermal mixing valve |
|||
-CP1.1-QN17 |
Pressure reduction valve |
Included in accumulator tank |
||
-CP1-QN17 |
Pressure reduction valve |
Included in accumulator tank |
||
-CP1.1-QM30 |
Shut-off valve |
|||
-CP1-QM30 |
Shut-off valve |
|||
-CP1.1-QM40 |
Shut off valve |
Included in accumulator tank |
||
-CP1.2-QM40 |
Shut off valve |
Included in accumulator tank |
||
-CP1.1-RM1 |
Non-return valve |
|||
-CP1-RM1 |
Non-return valve |
|||
-CP1.1-WM3.1 |
Tundish, cold water |
Included in accumulator tank |
||
-CP1-WM3.1 |
Tundish, cold water |
Included in accumulator tank |
||
-CP1.1-WM3.2 |
Tundish, T&P valve |
Included in accumulator tank |
||
-CP1.2-WM3.2 |
Tundish, T&P valve |
Included in accumulator tank |
||
-CP1-WM3.2 |
Tundish, T&P valve |
Included in accumulator tank |
||
-CP1.1-RN1.1 |
Trim valve |
|||
-CP1-RN1.1 |
Trim valve |
|||
-CP1-RN1 |
Trim valve |
|||
-CP1.1-RN1.2 |
Trim valve |
|||
-CP1-RN1.2 |
Trim valve |
|||
-CP1.2 |
Storage tank |
|||
-CP1.2-RN1.1 |
Trim valve |
|||
-CP1.2-RN1.2 |
Trim valve |
|||
-RN60 |
Trim valve |
|||
-RN61 |
Trim valve |
|||
-CP2-FQ1 |
Thermal mixing valve |
Part no. 624 922 |
||
-CP4 |
Additional water heater |
|||
-CP10.4 |
Tanks |
|||
-CP10 |
Buffer vessel |
UKV |
Size varies depending on the dimensioning of hot water |
|
-CP10.1 |
Buffer vessel |
UKV |
Size varies depending on heat pump and system volume |
|
-CP10.2 |
Buffer vessel, cooling |
UKV |
Condensation-insulated vessels for cooling Size varies depending on heat pump and system volume |
|
-CP10.3 |
Buffer vessel |
UKV |
Size varies depending on the dimensioning of hot water |
|
-CP10.4 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-CP10.5 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-CP10.6 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-CP10.7 |
Storage tank |
UKV 20-750 / UKV 20-1000 |
Size varies depending on the dimensioning of hot water |
|
-EB1 |
Step-controlled additional heat/electric boiler |
Modbus: 1029 (input) |
||
-EB1-AA25 |
AXC module |
Included in AXC 30 |
067 304 |
|
-EB1-BT25 |
Supply temperature sensor, heating medium, external |
Included in AXC 30 Modbus: 39 (input) |
||
-EB1-BT52 |
Boiler sensor |
Included in AXC 30 Modbus: 38 (input) |
||
-EB1-CM5 |
Closed expansion vessel, heating medium |
|||
-EB1-EP7 |
District heating exchanger |
|||
-EB1-FL2 |
Safety valve, heating medium |
|||
-EB1-GP10 |
Circulation pump, heating medium external |
Modbus: 1825 |
||
-EB1-QM40 |
Shut-off valve |
|||
-EB1-QM41 |
Shut-off valve |
|||
-EB1-QN11 |
Shuttle valve |
See the valve’s manual for a port description. |
||
-EB1-RM5 |
Non-return valve |
|||
-RN1 |
Trim valve |
|||
-EB2 |
External electrical backup |
|||
-EB3 |
Immersion heater in tank |
with junction box K11 |
IU 3 kW: 218 009 IU 6 kW: 218 011 IU 9 kW: 218 003 018 893 |
|
-EB3-QA1 |
Auxiliary relay |
HR 10 |
067 309 |
|
-EB15 |
Indoor module |
SMO S40 |
||
-EB15-BT1 |
Outside sensor |
Included in SMO S40 Modbus: 1 (input) |
||
-EB15-BT25 |
External supply temperature sensor |
Included in AXC 30 Modbus: 39 (input) |
||
-EB15-BT71 |
External return line sensor |
Included in AXC 30 Modbus: 39 (input) |
||
-EB15-BT25_extcp |
External supply temperature sensor |
Modbus: 39 (input) |
||
-EB15-CM4 |
Expansion vessel, hot water |
|||
-EB15-GP10 |
Circulation pump, heating medium external |
Modbus: 1825 |
||
-EB15-FL1 |
Safety valve, cold water |
|||
-EB15-FL2 |
Safety valve, heating medium |
|||
-EB15-RM2 |
Non-return valve |
|||
-EB15-QM30 |
Shut-off valve, hot water |
|||
-EB15-QN43 |
Bypass valve, cooling operation |
|||
-EB15-WM4 |
Tundish, T&P valve |
Included in SMO S40 |
||
XL |
XL connections |
|||
1 |
Heating medium connection, supply |
|||
2 |
Heating medium connection, return |
|||
3 |
Cold water connection |
|||
4 |
Hot water connection |
|||
5 |
Hot water circulation connection |
|||
6 |
Brine connection, in |
|||
7 |
Brine connection, out |
|||
8 |
Docking connection, supply (from heat pump) |
|||
9 |
Docking connection, return (to heat pump) |
|||
13 |
Solar heat connection, supply |
|||
14 |
Solar heat connection, return |
|||
18 |
Docking connection, supply (high temp) |
|||
19 |
Docking connection, return (high temp) |
|||
29 |
T&Pvalve |
|||
30 |
Expansion vessel connection |
|||
36 |
Heating medium connection, supply |
|||
37 |
Heating medium connection, return |
|||
39 |
Docking connection, pool |
|||
-EM1 |
Shunt controlled additional heat |
|||
-EM1-AA25 |
AXC module |
Included in AXC 30 |
067 304 |
|
-EM1-QN11 |
Shunt valve for additional heat |
Modbus: 1034 (input) |
||
-EM1-BT52 |
Boiler sensor |
Modbus: 38 (input) |
||
-EM1-BT25 |
Supply temperature sensor, heating medium, external |
Included in AXC 30 Modbus: 39 (input) |
||
-EM1-CM11 |
Expansion vessel |
|||
-EM1-FL2 |
Safety valve, heating medium |
|||
-EM1-FQ2 |
Thermal mixing valve |
Included in AXC 30 Modbus: 39 (input) |
||
-EM1-GP10 |
External heating medium pump |
Modbus: 1825 |
||
-EM1/EB1 |
Electric boiler, wood boiler, pellet boiler, oil boiler or district heating |
|||
-EM1/EB1-GP10 |
Circulation pump |
Modbus: 1825 |
||
-EP1 |
District heating |
Cetetherm Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP1-AA25 |
AXC module |
Included in AXC 30 |
067 060 |
|
-EP1-BT25 |
External supply temperature sensor |
Included in AXC 30 Modbus: 39 (input) |
||
-EP1-BT52 |
Boiler sensor |
Included in SMO S40 Modbus: 38 (input) |
||
-EP1-CM5 |
Closed expansion vessel, heating medium |
|||
-EP1-EP3 |
District heating exchanger, hot water |
|||
-EP1-EP7 |
District heating exchanger |
|||
-EP1-FL2 |
Safety valve, heating medium |
|||
-EP1-GP10 |
Circulation pump, heating medium external |
Modbus: 1825 |
||
-EP1-QN11 |
Mixing valve, addition |
See the valve’s manual for a port description. Modbus: 1034 (input) |
||
-EP1-RM1 |
Non-return valve |
|||
-EP1-CT1 |
District heating |
Cetetherm Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP1-CT2 |
District heating |
Cetetherm Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP1-CT3 |
District heating |
Cetetherm Midi Wall VP / Maxi VP |
Cetetherm AB |
|
-EP1-QM40 |
Shut off valve |
|||
-EP1-RN1 |
Trim valve |
|||
-EP10 |
Shunt controlled brine |
|||
-EP10-AA25 |
AXC module |
Included in AXC 30 |
067 060 |
|
-EP10-BT26 |
Temperature sensor, brine in |
Included in AXC 30 Modbus: 106 (input) |
||
-EP10-QN41 |
Shunt valve, brine |
Modbus: 1 See the valve’s manual for a port description. |
||
-EP10-EP10 |
Heat exchanger |
|||
-EP12 |
Ground water system |
|||
-EP12-AA25 |
AXC module, groundwater |
Included in AXC 30 |
067 060 |
|
-EP12-EP4 |
Groundwater exchanger |
|||
-EP12-GP3 |
Circulation pump, groundwater |
Modbus: 1835 (input) |
||
-EP12-HQ40 |
Particle filter, groundwater |
|||
-EP21 |
Climate system 2 |
AXC 30 |
067 304 |
|
-EP21 |
Climate system 2 |
AXC 30 |
067 304 |
|
-EP21-AA25 |
AXC module, heating system 2 |
Included in AXC 30 |
||
-EP21-BT2 |
Supply temperature sensor, heating system 2 |
Included in AXC 30 Modbus: 4 (input) |
||
-EP21-BT3 |
Return line sensor, heating system 2 |
Included in AXC 30 Modbus: 78 (input) |
||
-EP21-GP10 |
Circulation pump, heating system 2 |
Modbus: 1824 (input) |
||
-EP21-QN25 |
Shunt valve, heating system 2 |
Modbus: 1031 (input) See the valve’s manual for a port description. |
||
-EP21-RM1 |
Non-return valve |
|||
-EP22 |
Climate system 3 |
AXC 30 |
067 304 |
|
K |
Climate system 3 |
AXC 30 |
067 304 |
|
-EP22-AA25 |
AXC module, heating system 3 |
Included in AXC 30 |
||
-EP22-BT2 |
Supply temperature sensor, heating system 3 |
Included in AXC 30 Modbus: 3 (input) |
||
-EP22-BT3 |
Return line sensor, heating system 3 |
Included in AXC 30 Modbus: 77 (input) |
||
-EP22-GP10 |
Circulation pump, heating system 3 |
Modbus: 1823 (input) |
||
-EP22-QN25 |
Shunt valve, heating system 3 |
Modbus: 1031 (input) See the valve’s manual for a port description. |
||
-EP22-RM1 |
Non-return valve |
|||
-EP26 |
HRV unit |
ERS |
||
-EP30 |
Solar heating system |
SCA 35 |
067 245 |
|
-EP30-AA25 |
AXC module |
Included in SCA |
||
-EP8 |
Solar panels |
|||
-EP30-EP9 |
Exchanger, solar |
|||
-EP30-GP10 |
Circulation pump |
|||
-EP44 |
Cooling system 1 |
AXC 30 |
067 304 |
|
-EP44-AA25 |
AXC module, cooling system 1 |
Included in AXC 30 |
||
-EP44-BT2 |
Supply temperature sensor, cooling system 1 |
Modbus: 4 (input) |
||
-EP44-BT3 |
Return line sensor, cooling system 1 |
Modbus: 78 (input) |
||
-EP44-BT64 |
Flow temperature sensor, cooling |
Included in AXC 30 Modbus: 30 (input) |
||
-EP44-BT65 |
Return line sensor, cooling |
Included in AXC 30 Modbus: 31 (input) |
||
-EP44-GP10 |
Circulation pump, cooling system 1 |
Modbus: 1825 |
||
-EP44-QN18 |
Shunt valve, cooling system 1 |
Modbus: 1570 (input) See the valve’s manual for a port description. |
||
-EP44-RM1 |
Non-return valve |
|||
-EP45 |
Cooling system 1 |
|||
-EP45-AA25 |
AXC module, cooling system 1 |
Included in AXC 30 |
067 060 |
|
-EP45-GP10 |
Circulation pump, cooling system 1 |
Modbus: 1825 |
||
-EP25 |
Passive cooling system |
AXC 30 |
067 296 |
|
-EP25-AA25 |
AXC module, cooling |
Included in AXC 30 |
||
-EP25-BT64 |
Temperature sensor, cooling flow line |
Included in AXC 30 Modbus: 30 (input) |
||
-EP25-BT65 |
Temperature sensor, cooling return line |
Included in AXC 30 Modbus: 31 (input) |
||
-EP25-EP13 |
Supply air coil/fan coil |
|||
-EP25-GP13 |
Circulation pump, cooling |
Modbus: 1833 (input) |
||
-EP25-QN18 |
Mixing valve, cooling |
Modbus: 1570 (input) See the valve’s manual for a port description. |
||
-EP25-RM1 |
Non-return valve |
|||
-EQ1 |
Cooling |
AXC 30 |
067 304 |
|
-EQ1-AA25 |
AXC module, cooling |
Included in AXC 30 |
||
-EQ1-BP6 |
Pressure gauge, brine |
|||
-EQ1-BT57 |
Temperature sensor, collector |
Included in AXC 30 Modbus: 90 (input) |
||
-EQ1-BT64 |
Flow temperature sensor, cooling |
Included in AXC 30 Modbus: 30 (input) |
||
-EQ1-BT75 |
Temperature sensor, flow line after heat dump |
Included in AXC 30 Modbus: 91 (input) |
||
-EQ1-CM3 |
Expansion vessel, brine |
|||
-EQ1-EP6 |
Heat exchanger |
|||
-EQ1-EP18 |
Coolant radiator |
|||
-EQ1-FL3 |
Safety valve, brine |
|||
-EQ1-GP10 |
Circulation pump |
|||
-EQ1-GP12 |
Circulation pump |
Included in AXC 30 |
||
-EQ1-GP14 |
Circulation pump for heat dump |
|||
-EQ1-GP20 |
Circulation pump, heat dump |
|||
-EQ1-QM40.1 |
Shut-off valve |
|||
-EQ1-QM40.2 |
Shut-off valve |
|||
-EQ1-QN12 |
Reversing valve, cooling |
Modbus: 1830 (input) See the valve’s manual for a port description. |
||
-EQ1-QN18 |
Shunt valve, cooling shunt |
Modbus: 1570 (input) See the valve’s manual for a port description. |
||
-EQ1-QN36 |
Shunt valve, heating shunt |
Modbus: 1569 (input) See the valve’s manual for a port description. |
||
-EQ1-QN44 |
Shut off valve |
|||
-EQ1-RM1 |
Non-return valve, heat dump |
|||
-EQ1-RM2 |
Non-return valve, heat dump |
|||
-EQ1-RM3 |
Non-return valve, heat dump |
|||
-GC1 |
Solar panels |
NIBE PV |
||
-QZ1 |
Hot water circulation (HWC) |
|||
-QZ1-AA25 |
AXC module |
Included in AXC 30 |
067 304 |
|
-QZ1-BT70 |
Supply temperature sensor, HWC |
Included in AXC 30 Modbus: 87 (input) |
||
-QZ1-BT82 |
Return line sensor, HWC |
Included in AXC 30 Modbus: 174 (input) |
||
-QZ1-FQ3 |
Mixer valve, HWC |
|||
-QZ1-GP11 |
Circulation pump, HWC |
Modbus: 1063 (input) |
||
-QZ1-QN2 |
4-way valve, HWC |
See the valve’s manual for a port description. |
||
-QZ1-RM1 |
Non-return valve, HWC |
|||
-QZ1-RN1 |
Trim valve, HWC |
|||
-QZ1-RN4 |
Trim valve, HWC |
|||
-XL27 |
Filling connection |
|||
-QM33 |
Shut off valve, brine flow |
|||
-XL27 |
Filling brine |
|||
-XL28 |
Filling brine |
|||
-FL2 |
Miscellaneous |
|||
-BP5 |
Pressure gauge, heating medium |
|||
-BP6 |
Pressure gauge, brine |
|||
-CM1 |
Expansion vessel, heating medium |
|||
-CM2 |
Level vessel, brine |
|||
-CM3 |
Expansion vessel, brine |
|||
-CM4 |
Expansion vessel, hot water |
Included in SMO S40 |
||
-CM11 |
Expansion vessel |
|||
-FL1 |
Safety valve, hot water |
|||
-FL2 |
Safety valve, heating medium |
|||
-FQ1 |
Mixing valve |
Thermal |
||
-RM1 |
Non-return valve |
|||
-RM1.1 |
Non-return valve |
|||
-RM1.2 |
Non-return valve |
|||
-RM1.3 |
Non-return valve |
|||
-RM2 |
Non-return valve |
|||
-RM3 |
Non-return valve |
|||
-RN1 |
Trim valve |
|||
-RN1.1 |
Trim valve |
|||
-RN1.2 |
Trim valve |
|||
-RN1.3 |
Trim valve |
|||
-RN2.1 |
Trim valve |
|||
-RN2.2 |
Trim valve |
|||
-RN3.1 |
Trim valve |
|||
-RN3.2 |
Trim valve |
|||
-RN4.1 |
Trim valve |
|||
-RN4.2 |
Trim valve |
|||
-RN5.1 |
Trim valve |
|||
-RN5.2 |
Trim valve |
|||
-QM1 |
Drain valve, heating medium |
|||
-QM30 |
Shut-off valve, hot water |
|||
-QN17 |
Pressure reduction valve |
|||
-QN44 |
Shut off valve |
|||
-WM3 |
Tundish, cold water |
Included in SMO S40 |
||
-WM4 |
Tundish, T&P valve |
Included in SMO S40 |
Designations according to standard EN 81346-2.