-EP21-GP10 -EP21- B T2 -EP 21 - AA2 5 -EP21- B T3 -EP21-QN25 -EP21 -EB15 -EB101-QM1 XL1 XL2 -EB 101 -QM 4 0 -EB101-QZ2 -EB101-FL10 -EB101-RM1 -EB15- B T1 -EB101 -EB101 XL 8 1 2 4 3 9 - WM3 XL 8 1 2 4 3 9 29 5 -EB15 XL 8 2 4 3 9 1 -QZ 1 -F Q 3 -QZ1-GP11 -QZ 1 -RM 1 -QZ1-RN1 -QZ1 5 -CP4 -QZ 1 -F Q 3 -QZ1-GP11 -QZ 1 -RM 1 -QZ1-RN1 -QZ1 -EQ1-QN12 -EQ1 - AA25 -EQ1-GP12 -EQ1 -CP10.2 -EP45 -EQ 1 - B T6 4 -RM1 - AZ10-GP12 - AZ10-HQ1 - AZ10 -QN44 -EB1 - AA25 -EB1 -EB15- B T25 -EM1 - AA25 -EM1- B T52 -EM1-QN11 -EM1 -EM 1 -EB15- B T25 -CL11-GP12 -C L11 -GP 9 -CL11- B T51 -CL11-EP5 -CL11 - AA25 -CL11 -CL11-HQ4 -CL11-QN19 -CP10.1 -EB15- B T25 -EB15-GP10 - AZ30 -GC1

Protective and safety equipment as well as components that facilitate servicing (e.g. non-return valves, safety valves, bypass valves, shut-off valves) must be installed in accordance with national regulations and standards. The installation must be dimensioned to cope with the minimum defrosting flow at 100% charge pump operation.

Important component information

Pay attention to supplementary information for the following components:

Function

Heat pump

The compressor in a S2125/F2120/F2050 is inverter-controlled. The compressor’s power is adjusted according to the demand and it is routed to heating, hot water, cooling or pool heating.

Operating modes

Heat production

VVM S320 is supplied with a heating control system, which means that the heating supply to the house takes place according to selected settings. When connecting to a system with thermostats on all radiators (or underfloor heating coils), either a bypass valve must be fitted or some of the thermostats must be removed to ensure there is sufficient flow. For more information about heat production, see the Installer Manual.

Hot water production

VVM S320 consists of a storage heater that is heated with a charge coil.

When there is demand for hot water, VVM S320 prioritises this and switches to hot water mode. There is no heat production in this mode.

If the hot water temperature exceeds 60 °C, the installation must be supplemented with a mixing valve.

For more information about hot water production, see the manual for VVM S320.

Functions/accessories

Heating system 2

This function requires the NIBE ECS 40/41 accessory. Shunt valve, supply and return line sensors, as well as circulation pump, are connected to other heating circuits with a lower temperature demand (e.g. underfloor heating system). The temperature in the extra heating system follows the selected curve slope and offset setting. Up to 8 extra heating systems can be connected to the installation.

For further information, see the Installer Manual for the accessory.

See the valve’s manual for a port description.

Extra hot water heaters

The system should be supplemented with an extra water heater, if a large bath tub or other significant consumer of hot water is installed.

Hot water circulation

A circulation pump can be controlled by VVM S320 to circulate the hot water. The circulating water must have a temperature that prevents bacterial growth and scalding, and national standards must be satisfied. See the appropriate Installer Manual for more information.

The hot water circulation pump can be connected via an AUX output in VVM S320. If the AUX output is being used for any other function, the hot water circulation pump can instead be connected via the accessory AXC 40. The hot water circulation pump can be connected via the following functions:

  • hot water comfort (accessory AXC 40)

HRV unit

This function requires the accessory ERS, which is controlled by VVM S320. ERS recovers the energy from the ventilation air and supplies it to the property.

For further information, see the Installer Manual for the accessory.

Exhaust air recovery

This function requires the accessory S135. S135 is an exhaust air module that is controlled by VVM S320. S135 recovers energy from the ventilation air and supplies it to the property.

For further information, see the Installer Manual for the accessory.

Cooling (in 4-pipe system)

With the accessory ACS 310, separate cooling and heating systems can be connected via a reversing valve. The cooling system is connected between the heat pump and the indoor module.

When cooling is required (activated from the outdoor temperature sensor EB15-BT1 and room sensor EB15-BT50, where applicable), the shunt valve EQ1-QN12 and the circulation pump EQ1-GP12 are activated.

See the valve’s manual for a port description.

Pool

With the POOL 310 accessory, the heat pump can be used to heat a pool.

For further information, see the Installer Manual for the accessory.

Buffer vessel (UKV)

A buffer vessel is an accumulator tank that is suitable for connection to a heat pump or another external heat source, and can have several different applications.

For further information, see the Installer Manual for the accessory.

Solar panels

This function requires the NIBE PV accessory. NIBE PV is a complete modular system with solar panels in several basic outputs. NIBE PV is connected to VVM S320, which adjusts to the generated solar electricity produced.

For further information, see the Installer Manual for the accessory.

Addition

Additional heat that requires the AXC 40 accessory. AXC 40, via a control signal, can control step-controlled additional heat.

The additional heat is used for heat production.

For further information, see the Installer Manual for the accessory.

Shunt controlled additional heat

Additional heat that requires the AXC 40 accessory. AXC 40, via a control signal, can control additional heat, which can also be prioritised.

The additional heat is used for heat production.

For further information, see the Installer Manual for the accessory.

List of components

Designation

Name

Specification

Part No.

Comments

-EB15

Indoor module

NIBE VVM S320

-EB15-BT1

Outside sensor

Included in VVM S320

-EB15-BT25

External supply temperature sensor

-EB15-FL1

Safety valve domestic water

-EB15-FL2

Safety valve, heating medium

-EB15-GP10

External heating medium pump

-EB101

Heat pump

S2125/F2120/F2050

-EB101-FL10

Safety valve, heating medium

-EB101-QM1

Shut-off valve, heating medium

-EB101-QM40

Shut-off valve, heating medium

-EB101-QZ2

Filterball, heating medium

Included in S2125/F2120/F2050

-EB101-RM1

Non-return valve, heating medium

XL1

Heating medium connection, supply

XL2

Heating medium connection, return

XL

XL connections

1

Heating medium connection, supply

2

Heating medium connection, return

3

Cold water connection

4

Hot water connection

5

Hot water circulation connection

8

Docking connection, supply (from heat pump)

9

Docking connection, return (to heat pump)

-AZ10

Exhaust air module

NIBE S135

067 075

-AZ10-GP12

Circulation pump

Included in S135

-AZ10-HQ1

Particle filter

-CL11

Pool system

POOL 310

067 247

-CL11-AA25

AXC module

Included in POOL 310

-CL11-BT51

Pool sensor

Included in POOL 310

-CL11-EP5

Exchanger, pool

-CL11-GP9

Circulation pump, pool

-CL11-GP12

Charge pump, pool

Included in POOL 310

-CL11-HQ4

Particle filter, pool

-CL11-QN19

Three way valve, pool

Included in POOL 310

See the valve’s manual for a port description.

-AZ30

HRV unit

NIBE ERS

-CP4

Additional water heater

-CP10.1

Buffer vessel

UKV

Size varies depending on heat pump and system volume.

-CP10.2

Buffer vessel, cooling

UKV

Size varies depending on heat pump and system volume.

-EB1

Step-controlled additional heat/electric boiler

-EB1-AA25

AXC module

Included in AXC 40

067 060

-EM1

Shunt controlled additional heat

-EM1-AA25

AXC module

Included in AXC 40

067 060

-EM1-BT52

Boiler sensor

Included in AXC 40

-EM1-QN11

Shunt valve for additional heat

-EP21

Climate system 2

NIBE ECS 40/41

067 287 / 067 288

-EP21-AA25

AXC module

Included in NIBE ECS 40/41

-EP21-BT2

Supply temperature sensor, climate system 2

Included in NIBE ECS 40/41

-EP21-BT3

Return line sensor, climate system 2

Included in NIBE ECS 40/41

-EP21-GP10

Circulation pump, climate system 2

Included in NIBE ECS 40/41

-EP21-QN25

Shunt valve, climate system 2

Included in NIBE ECS 40/41

See the valve’s manual for a port description.

-EP45

Cooling system 1

-EQ1

Cooling

NIBE ACS 310

-EQ1-AA25

AXC module

Included in NIBE ACS 310

-EQ1-BT64

Flow temperature sensor, cooling

Included in NIBE ACS 310

-EQ1-GP12

Circulation pump

Included in NIBE ACS 310

-EQ1-QN12

Reversing valve, heating/hot water

Included in NIBE ACS 310

See the valve’s manual for a port description.

-GC1

Solar panels

NIBE PV

-QZ1

Hot water circulation (HWC)

-QZ1-FQ3

Mixer valve, HWC

-QZ1-GP11

Circulation pump, HWC

-QZ1-RM1

Non-return valve, HWC

-QZ1-RN1

Trim valve, HWC

XL

Miscellaneous

-RM1

Non-return valve

-RM2

Non-return valve

-QN44

Shut off valve

-WM3

Tundish

Designations according to standard EN 81346-2.